Additional information
Origin | Mainland China |
---|---|
Feature | Stocked |
Model Number | DQ7 |
Material | Plastic |
Type | Kitchen Lighters |
Certification | CE / EU |
67.50 $
46 in stock
Origin | Mainland China |
---|---|
Feature | Stocked |
Model Number | DQ7 |
Material | Plastic |
Type | Kitchen Lighters |
Certification | CE / EU |
1, working voltage: AC220V 2, working voltage range: AC175-245V 3, service life: ≥100,000 times
4, ignition intensity: high-pressure powerful ignition, can ignite flammable gas and vaporized alcohol-based biofuels,
5, the igniter is sealed with epoxy resin, waterproof and moisture-proof.
6, ignition time: power on long ignition, continuous ignition.
Second, the commercial stove igniter – DQ7 lead wire plug connection instructions
1. Two high-voltage ignition wires 800mm are connected to the double-pin ignition needle for relative ignition, or one high-voltage ignition wire 800mm is connected to the ignition needle, and the other high-voltage ignition wire 800mm is connected to the furnace body, the ignition pin and the burner metal. The distance between the two is 5-6mm, and the ignition is discharged for the burner to form an ignition circuit. Ignition high-voltage line connection: The company strongly recommends that the customer use the dual-purpose ignition for the ignition needle. This kind of ignition effect is better. If the double-needle can only be used with a single needle because of the burner, one of the high-voltage output leads 800mm Connect the ceramic ignition needle, another high-voltage output lead 800mm must be fixed on the burner with screws. The distance between the ignition needle and the metal of the burner is 5-6mm. The ignition is discharged against the burner to form an ignition circuit. Note that it is not on the stove, it is not attached to the hob. If it is connected to the hob, the ignition circuit is very long. Moreover, the hob and the burner are not necessarily connected, so the ignition is cut off. In the loop, the igniter only uses half the power. Maybe you can hardly understand the truth at the same time. Maybe you will say that I have been connected in this way. It is very good. You just have to try it. So the igniter output high voltage line produced by our company is double long line. For a length of 800mm, refer to the igniter connection diagram below.
2, the input red high temperature line 500mm connected to 220V mains.
3, in order to facilitate the installation, you can customize the length of the cable plug and the connection terminal according to customer needs. High-voltage line terminal block as shown
Third, commercial stove igniter – DQ7 working process
1. Turn on the 220V power switch and ignite the ignition. At this time, turn on the gas valve of the stove to ignite the combustible gas or alcohol-based fuel and enter the normal combustion state. At this time, the igniter is continuously ignited.
2. If you want to stop the stove work, first close the air valve, then turn off the 220V power switch.
3, the company's commercial stove igniter series products, there are a variety of models for customers to choose, can also be customized according to customer requirements.
Fourth, high frequency high energy igniter installation precautions
1. The installer must have an electrician installation qualification.
2. 2. The rated input voltage of this igniter is 220V 50HZ. A qualified leakage circuit breaker must be installed at the front end of the power supply. The metal casing of the cooker must be protected by a grounding wire. It is strictly forbidden to connect the metal casing with a neutral wire!
3. The control switch on the panel should use a bipolar power switch of not less than 5A/250V, and the igniter power cord is connected to the power switch.
4. 4. The igniter can be fixed or suspended in the lower space of the cooker, and high temperature radiation baking should be avoided.
5, 5. High-voltage line is connected to the ignition needle. It is recommended to use dual-ignition ignition mode. The discharge spacing of the ignition needle is 3-5mm. Try not to use the single-discharge method. If only one high-voltage line is connected to the ignition needle, the other high-voltage line must be reliably connected. On the metal body of the burner, it can not be easily connected to the metal casing of the cooker, which will bring many difficult problems!
6. 6. The length of the high-voltage line is “long enough and shortest”. It is better to separate the two lines by more than 3 cm, and keep a certain degree of drooping arc to facilitate the oil drop. The high-voltage line can not be extended continuously. The wiring is not allowed to be close to the iron frame and iron plate of the stove. Do not add all kinds of casings. Never use the two high-voltage wires to twist together to avoid high-frequency high-voltage leakage!
7. Regularly clean up debris and do not rinse with water.
Five, the main product type of commercial stove igniter
The commercial stove igniter series products produced by our company are divided into powerful igniter, super igniter and high-energy igniter according to the ignition intensity. There are two kinds of delay ignition and continuous ignition according to the ignition mode. Electric start, jog button start and switch start, as well as output control fan start, so the following series of products have been produced, customers can purchase according to needs, or customize products according to customer requirements.
1; Strong ignition: This type of igniter is suitable for igniting flammable gas or vaporized alcohol-based fuel, and can also ignite high-purity liquid alcohol-based fuel.
2; super ignition: This type of igniter can ignite flammable gas and alcohol-based fuel, and the ignition needle can be ignited with a little water. It is especially suitable for point-based alcohol-based fuels, which contain different proportions of water in alcohol-based fuels.
3; high-energy ignition: This type of igniter has the strongest ignition capacity. The spark is like a flame. It can ignite some difficult fuels. It is also suitable for large-scale cooking stoves with fans. Because of the fan, the ignition sparks are scattered. Increasing the ignition area makes it easier to catch fire. Customers can choose according to their needs.
The commercial stove igniter produced by our company mainly has the following functions:
1, continuous ignition; ignition after powering until the power is turned off,
2, delay ignition; ignition after ignition for a certain time will automatically stop ignition, a certain time is generally 10-12 seconds, can also be set according to customer needs. If some customers require a delay ignition time of 20 seconds. The advantage of using such an igniter is that the life of the igniter is greatly extended.
3. The low-voltage jog button switch is activated; the igniter has a set of low-voltage switch start leads connected to the low-pressure push button switch to realize the low-voltage start igniter. This ignition mode is safer, not afraid of leakage and electric shock, and the low-voltage switch starts a little moving and button Self-locking, this is based on the user's habits.
4, synchronous control of the fan; igniter has a set of 220V voltage output leads, can be used to control the fan or electromagnetic pump.
The above functions can be selected according to their own needs. If there are other functions to be implemented, they can be customized.
The main products of the igniter produced by the company are as follows. 1, DQ7: 220V continuous powerful ignition. 2, DQ2: 220V with extended powerful ignition. 3, DQ6: 220V continuous super ignition. 4, DQ3: 220V with time delay super ignition.
5, DQ5: 220V with time delay super ignition, low pressure button start.
6, DQ8: 220V with time delay super ignition, low pressure button start, synchronous control fan or electromagnetic pump. 7, DY3: 220V continuous high-energy ignition. 8, DY1: 220V with delayed high-energy ignition.
9, DY2: 220V with delayed high-energy ignition, low-voltage button to start.
10, DY6: 220V with delayed high-energy ignition, low-pressure button start, synchronous control of the fan or electromagnetic pump.
DQ8 basic parameters The DQ8 high-energy igniter developed by the company is AC220V igniter, with strong ignition capability, stable and reliable performance and high ignition efficiency. It is widely used in commercial energy-saving stoves, boilers, burners, steamers, ovens and other commercial equipments that use gas and methanol as fuel. 1, product model: DQ8. 2, the main function: delay super ignition, low-voltage switch start. 3, working voltage range: AC175V-245. 4, the service life: ≥ 100,000 times. 5, ignition intensity: super ignition, can ignite flammable gas and various alcohol-based biofuels. 6, ignition high pressure: ≥ 15Kv. 7, delay to stop the ignition [...]
78.75 $ Add to cartFunctional Overview BF-15B + microcomputer temperature difference controller, directly set the temperature difference upper limit to achieve the effect of temperature control of the water cycle, the panel is simple and convenient to operate. To make hot and cold water cycle, mainly by improving the thermal efficiency high and low temperature difference between the value measured by the sensor and the upper and lower limit set temperature difference. Mainly used in hot water circulation system backwater control. The main function Function Name Function Description Temperature control when the temperature difference T ≤T limit, normally open relay disconnected, normally closed pull; [...]
82.00 $ Add to cartFully compatible with the general-purpose OCE-K339L controller, the materials are more sophisticated, the performance is more stable, and the anti-interference is stronger. Upgrade does not increase the price, if our improvement can improve your quality, I DO. 1. Plate upgrade: It adopts Aobolai KB Class A FR4 glass fiber board, which has better electrical performance and higher safety. 2, process upgrade: SMD surface patch technology, double-sided wiring design, automatic production efficiency, more stable performance; buzzer built-in, to avoid collision during transportation and use the housing to expand the sound, the sound is louder. 3, program upgrade: the main control chip [...]
115.00 $ Add to cartY2 commercial gas stove flameout safety protection ignition controller function description The controller is used on commercial stoves to realize automatic high-energy ignition and accidental flameout protection to meet the automatic control and safety protection of modern kitchen stoves. First, Y2 commercial stove flameout safety protection controller basic parameters 1, product model: Y2. 2, working voltage range: AC175-245V 3, service life: ≥100,000 times 4, ignition intensity: high-energy ignition, can easily ignite combustible gases and various alcohol-based biofuels. 5, there is an accidental flameout safety protection function, when the accidental flameout, the solenoid valve is closed and an alarm sounds. 6, [...]
158.75 $ Add to cartCommercial stove infrared anti-air burning controller function description The controller is a commercial stove controller without fan control the fan can be independently controlled, which can realize automatic high-energy ignition and anti-air burning, and meet the needs of automatic control and safety protection of modern kitchen stoves. Controller working process: The controller turns on the power switch, starts ignition, opens the oil valve, and after 12 seconds, the ignition stops and enters the combustion state. At this time, the infrared sensor head and the receiving head constitute a pot sensor to detect whether there is a pot on the furnace, [...]
177.50 $ Add to cartCommercial stove infrared anti-air burning controller function description The controller is a commercial stove controller without fan control the fan can be independently controlled, which can realize automatic high-energy ignition and anti-air burning, and meet the needs of automatic control and safety protection of modern kitchen stoves. Controller working process: The controller turns on the power switch, starts ignition, opens the air valve, and after 12 seconds, the ignition stops and enters the combustion state. At this time, the infrared sensor head and the receiving head constitute a pot sensor to detect whether there is a pot on the furnace, [...]
177.50 $ Add to cartN series atomization controller description This series of controllers is used in conjunction with a methanol spray burner for ignition and fire regulation. With the extinguishing function, it can be used in places such as steaming furnaces. System parameter setting method: Press and hold the setting button to enter the system parameter setting, turn the knob to select the desired menu, press the setting button to display the value, turn the knob to adjust the value, and then press and hold the setting button until the SAU is displayed, indicating that the saving is successful. Note: If you do not [...]
177.50 $ Add to cartProduct model: 1.5V 5th battery One out single head External ignition switch Product Description: Original Italian SIT company produced igniter, quality assurance. With a 1.5V No. 5 alkaline battery, it is easier to use a longer lasting replacement. Another OMRON micro switch ignition switch line is available for sale. Applicable to Shenzhen Yufubao Shenzhen 100 years Nanjing Guanglong kitchen [...]
88.74 $ Add to cartChcę coś kupić ale szukam informacji jak zamówić... |
Kupiłem coś ale chcę poznać status zamówienia... |
Odebrałem paczkę ale mam pytanie lub problem... |
Chcę dokonać zwrotu i potrzebuję informacji... |
Droptech Sp. z o.o. droptech.polska@gmail.com |
ul. Łódzka 118, Piotrków Tryb. Sprzedajemy tylko przez internet |
NIP: 7712911090 REGON 386758083 |
Wysyłka bezpośrednio od producenta lub dostawcy |
DARMOWA WYSYŁKA + ubezpiecznie dostawy + śledzenie przesyłki |
CAŁKOWITY ZWROT podczas reklamacji |
# IQOS 2.4 |
Reviews
There are no reviews yet.